scxi-1314. 1 - Block Diagram and Interface Definition. scxi-1314

 
1 - Block Diagram and Interface Definitionscxi-1314  The task uses a SCXI-1000 chassis with a SCXI-1520 module and a SCXI-1314 terminal block

The value of the strain appear in LABVIEW EXPRESS. . com ¥ ni. By choosing this system over using benchtop instruments, United Technologies Research Center saved. 57 to 0. italic Italic text denotes variables, emphasis, a cross reference, or an introduction to a key concept. tion, conditioning (SCXI 1520, National Instruments) and transmission to the PC (SCXI 1600 DAQ module, National Instruments). I am doing a school project that involves gathering stress strain data from a SCXI1000 chassis. You also need either the SCXI‑1314 or SCXI‑1314T front mount terminal block to use the SCXI‑1520. connecting RS technology torque convertor to the wiring board of a ni scxi 1314, whats the best way considering that this reads botht the inputChange the type of sensor pressure strain for SCXI-1314. 将信号输入端子(scxi-1314上的s+和s-)与机箱的地相连。scxi-1314并没有aignd的接线端. SCXI™ Getting Started with SCXI. Offset. The SCXI-1314 (Part Number: 777687-14) is created for use with the SCXI-1520 universal strain/bridge module. The SCXI-1314 is a National Instruments Terminal Block with a Compatible Module SCXI-1520 . I have attempted to connect a strain Gauge to the SCXI 1314, but during data aquisition using measure and automation, there is absolutely no variation when its stimulated. The task has been configured from a full bridge type-I strain gauge with internal excitation. strain reading system included the acquisition of the signal (SCXI 1314, NI, National Instruments, Austin, Texas, USA), amplifica-. Are you in EU? Call: +44 1782 576800. Hi Ron, You can send them to OR get these calibrated, or you may have a local company. Technical Specifications. The informationHello all: I am currently using a PXI 1052 with an SCXI 1303 card and two SCXI 1314 cards on it. vi found in the examples sections of Labview as the foundation of my program. The SCXI-1326 terminal block is a shielded board with supports to connect it to the module front connector. We use a SHC-68-68EPM cable to connect the DAQcard to the scxi. {"payload":{"allShortcutsEnabled":false,"fileTree":{"":{"items":[{"name":"1. The SCXI-1330 kit has 32 terminals (rows A and C, even-numbered pins only). 10 pages. strain/bridge module enabling you to conveniently connect strain gauges. SCXI-1520 to SCXI-1314 Full-Bridge Connection. 4. . Then, follow the steps below: 1. The modules that fail exhibit noise on all channels. You also need either the SCXI‑1314 or SCXI‑1314T front mount terminal block to use the SCXI‑1520. The SCXI-1314 (Part Number: 777687-14) is created for use with the SCXI-1520 universal strain/bridge module. According to the manual of the module scxi-1314, everything we do is check the resistance and for the scxi-1520, it performs internal calibration. . 4. universal strain terminal block. EN English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian český. scxi-1314の端子台とscxi-1520モジュールを使用して、120Ωひずみゲージから信号を取りたいと考えています。daqmxを使用し、maxでグローバルチャンネルの設定を行いたいのですが、キャリブレーションを行うとエラーが出てしまいます。何の設定がおかしいのでしょうか。Summary of Contents for National Instruments SCXI-1000. 11. 1. 68-pin or 100-pin E/M/S Series multifunction data acquisition (DAQ) devices. I am using DAQmx Vis to program. an SCXI-1314 terminal block, connect the DMM to the P0+ and P0– output terminals of the SCXI-1314. . 1 as described in the preceding text. 115. Stock # 94460-1 . The connection chain would be strain gage----->SCXI 1314 (Terminal Block)----->SCI 1520 ( 2nd block). 4-12. The strain levels range from about zero to +/-1000ue (microstrain), and according to the NI 'Measuring Strain with Strain Gauges' tutorial this. Labview software (Labview 8. 08-14-2011 11:45 PM. 121. If you have an SCXI-2000 chassis, right-click its folder and select Properties. The load that a person experiences during a fall cannot be measured with volunteers for ethical reasons. There are 6 wires in the serial cable. com ¥ ni. See how we do it. The RN-55 style quarter-bridge completion resistors are provided in the SCXI-1314 front-mounting terminal block. Rtds. 14 The DA module SCXI 1000 is connected to a pentium-4 computer through PCI 6221 DA. Bold text also denotes parameter names. SCXI-1314 Home SCXI-1314. The SCXI-1314 terminal block is used with the SCXI-1520 universal strain/bridge module enabling you to conveniently connect strain gauges through screw terminals. The National Instruments SCXI-1314 Terminal Block is a front-mounting terminal block for the SCXI-1520 universal strain gauge input module, for use with 350 Ohm quarter bridge strain gauges. Specifications All specifications are typical at 25 °C unless otherwise specified. Radwell is not an authorized distributor, reseller or representative of the products featured on this website. Top and bottom stain gauges are connected to DA strain module for quarter bridges. After a recent test, I measured more than 4000 uStrain. 4. Technical Specifications Shipping Information In Stock Ships Today Request A. This document also. Fluke / NetScout OneTouch AT Dual Gigabit With Wi-Fi Base Network Tester. Analog Input Channels. Figure 2-1. For additional information refer to the SCXI-1352 Installation Guide and other NI documents at New to signal express and I have a few questions. The chassis is connected to a PXI-6250. Manuals for DVD Recorders. . 1 as described in the preceding text. It also contains instructions for verifying the performance of the temperature sensor for those. They are socketed,so you can replace them with your own resistors. The quarter-bridge completion resistor is in the SCXI-1314 terminal block and is socketed. Per the SCXI-1314 Terminal Block Calibration Procedure, there are two 100K high precision resistors installed to be used for shunt calibration procedures. Free essays, homework help, flashcards, research papers, book reports, term papers, history, science, politicsWelcome to part 6 in our ongoing series about the National Instruments SCXI platform!This blog post will describe several different SCXI terminal blocks. Connections, including power signals to ground and vice versa, that exceed any of the maximum signal ratings on the SCXI device can create a shock or fire hazard or can damage any or all devices conn ected to the SCXI chassis, th e host computer, and the SCXI device. Figure 3: Sample Connection Diagram for a Strain Gauge Input Task scxi-1314 터미널 블록은 센서에 편리하게 연결하기 위해 스크류 터미널을 제공합니다. Select an appropriate gain so that the amplified voltage is within the input range of the DAQ board. On the stationary side, the six strain signals were carried to an NI SCXI 1314 terminal block that was connected to an NI SCXI 1520 strain input module. Normally 3 cables per bridge enough for half bridge but for the shunt calbration I need 5 cables per channel. Instruments acquisition system composed of a SCXI-1000DC chassis, a SCXI-1600 data acquisition and control card for PC connection and a generic input module SCXI-1520 with a SCXI-1314 mount. 4. 00. SCXI-1305. SCXI-1314 - 4 nos. You may need to have the connector block to SCXI 1520 to connect your sensors to the SCXI 1520. SCXI Model Number: PXI Model Number: C Series Model Number SCXI-1000: PXIe-1071: cDAQ 9174 cDAQ 9184 SCXI-1000DC: PXIe-1071 PXIe-1082 (782946-01) cDAQ 9174 cDAQ 9184: Choose the PXIe-1071 if the application requires four PXIe slots; however, if DC power is a more important feature choose the PXIe-1082 (DC). 15. The quarter-bridge completion resistor has a factory default value o f 350 Ω for use with a 350 Ω strain gauge. . 12-09-2004 02:27 PM. Remote SCXI Devices. 0. Click Reprogram. LK - 29 Aug. Made By. com Do not loosen or re-orient the safety-ground lug hardware when connecting the safety-ground wire; to do so reduces the safety isolation between the high voltage and the SCXI-1520, and to a precision 100 kΩ shunt calibration resistor. 2) For the SCXI channel to view, use the following convention OB0!sc (n)!md (m)!ch where the letter (n) corresponds to the chassis number in MAX (usually = 1), the letter (m) corresponds to the module number (slot) where the module is located in the chassis, and (ch) represents the channel. Mod4: SCXI-1520 w/ SCXI-1314. 技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。SCXI-1320 Terminal Block SCXI-1314. 6 pages. Part Numbers:187212B-01, 777687-14 SCXI-1127. View Photo of missing side panel. . The mobile DAQ system achieves seamless integration among signal conditioning, data acquisition, and synchronization that benchtop instruments would not have achieved. SCXI-1338 Installation Manual. The NI SCXI-1520 (Part Number: 777966-20, 186338-01) Universal Strain-Gauge Input Module can be utilized with the SCXI-1314 Screw Terminal Block, the SCXI-1310 Connector and Shell Assembly, the TBX-96 DIN-rail mounted Terminal Block, or the SCXI-1314T RJ-50 Terminal Block. 115. It depends on how you're looking to do the calibration- to do a full calibration, you would want to reference the 1520 link that Chris posted, which requires a Fluke 5700A along with a DMM. $200. Remote SCXI Devices. Generated stress was calculated from measured force per unit area of initial material dimension. You can also read this on page 4-27 and 4-28 of the SCXI-1520 User Manual and Specifications. (+ SCA x 2) Is it really necessary to do shunt calibration. Do not directly connect S+ or P– to the SCA terminals inside the SCXI-1314 terminal block unless the st. National Instruments is not liable for any damages or injuries resulting from inadequate signal wire insulation. REPORT DOCUMENTATION PAGE Public reporting burden for this collection of information is estimated to average 1 hour per response, including iNational Instruments SCXI-1322 Temperature Sensor Terminal Block. Do not connect anything else to the DAQ board. The sequence File»Page Setup»Options directs you to pull down the File menu, select the Page Setup item, and select Options from the last dialog box. Minimum Repair Price is $200. 119. He is a list of the connections as well: P-. C. . National Instruments SCXI-1313A- 8 input channels: Call: SCXI-1314: National Instruments SCXI-1314- for use with the SCXI-1520: Call: SCXI-1315: National Instruments SCXI. Terminal Block National Instruments SCXI -1314 Installation Manual. I kept two load cells of 100 tonne capacity each of the same make one above the another between the cross heads of the UTM. I'm going to address your last question first. Terminal Block National Instruments SCXI -1314 Installation Manual. SCXI-1314 PLCs/Machine Control from NATIONAL INSTRUMENTS 2-Year Warranty, Radwell Repairs - DISCONTINUED BY MANUFACTURER, TERMINAL BLOCK, LOW VOLTAGE. SCXI-1349 cable assembly 4. 入力信号のプラス端子及びマイナス端子をSCXI-1314のそれぞれS+端子及びS-端子に接続してから、使用するDAQデバイスのテストパネルを開きます。「アナログ入力」タブ上でチャネルとしてob0!scX!mdY!nのように指定してください。The SCXI-1310, a 96-pin connector-and-shell assembly, is for use with low-voltage SCXI modules. No load applied; In the calibration table of DAQ task in MAX, the sensor showed zero. NI SCXI 1314 as an add-on (which houses the pins for analog connections). I have a manufactured load cell that I'm plugging into an SCXI-1314 wired for full bridge. The capabilities listed in this document represent capabilities available at National Instrument and Certified Calibration Center labs. . There are 10 pins arranged in eight modular jacks. This acquisition system allowed sampling at 12 ms intervals of all force transducers in the pyramidal balance. 3. 79 N⋅ m (5 to 7 lb - in. Half Bridge Schematic for SCXI Strain Components In order for LabVIEW software to integrate with NI data acquisition hardware and read the data, SCXI hardware needs to be virtually installed in LabVIEW environment. SCXI 1191; SCXI 1192; SCXI 1313; SCXI 1314; TBX 1316; Products Supported in Prior Versions of NI-DAQ Not Supported in This Version. com ¥ ni. The terminal block has 48 screw terminals for easy signal connections. italic Italic text denotes variables, emphasis, a cross reference, or an introduction to a key concept. Half-bridge completion is provided in the SCXI-1520, and you can enable it through software. 3. 7. Rated 4. We're using a scxi-1000 chassis with the scxi-1520 module and scxi-1314 terminal block. I have problem with obtaining strain with SCXI 1520 (with terminal block 1314). Refer to the SCXI Quick Start Guide to power on the SCXI chassis and configure the system in software. When you configure your SCXI-1520 in Measurement & Automation Explorer (MAX) you can also assign an accessory such as the SCXI-1314T to the module. 2) PXI System: PXI-8196 (RT-OS. An important added-value of CREPEC resides in the gathering and sharing of our members’ research infrastructures and expertise. 9 cm by 3. NI SCXI-1314 terminal block is used with the SCXI-1520 universal strain/bridge module enabling you to conveniently connect strain gauges through screw terminals. Inorder to find out whether the setup will suit to the measurements or not give in detail about the strain gauge you are using, sensitivity, bridge configuration you are using. The SCXI-1304 AC/DC is a shielded terminal block with screw terminals that you can connect to the SCXI-1140, SCXI-1141/1142/1143, SCXI-1120/D, SCXI-1125, or SCXI-1126 input connector. Any help would be appreciated. Data acquisition was accomplished utilizing a desktop computer and a National Instruments NI SCXI-1314 analog to digital conversion module. Set the following parameters: • SCXIchassisID—The value assigned by MAX • moduleSlot—1 • moduleChan—The channel number from step 3 • excitationType—2As mentioned, I'm configuring my 1520 and 1314 for 1/4 and full bridge. 884. 2. PXIe-4353 Installation Manual. I have tried the following:-Disconnect power, power back on-system OK for a few seconds, then fails to recognize anything-Swap out USB cable connecting the 1600 to the PC-no change in problemHi, How to configure in MAX the SCXI 1314(PXI 1052 and 1520) to take load cell measurement? I tried to create a task usin analog input ->strain, but it does not work. The National Instruments SCXI-1314 Terminal Block is a front-mounting terminal block for the SCXI-1520 universal strain gauge input module, for use with 350 Ohm quarter bridge. ThanksNI SCXI-1304 NI SCXI-1306 NI SCXI-1314 NI SCXI-1315 NI SCXI-1326 NI SCXI-1600. Expand the NI-DAQmx SCXI Chassis section and choose your chassis model and click Finish. National Instruments. Real or not (we think maybe it's a sign of bad) I feel like the ADC. This unit is missing the side panel; however, this does not affect its ability to function properly. As you can see in page 4 of the SCXI-1314 manual, both shunt calibration resistors A and B are have a value of 100 kohm. Our ISO/IEC 17025:2017 accreditation certifies our capabilities. Apex Waves carries obsolete National Instruments Signal Conditioning eXtensions for Instrumentation (SCXI) modules, chassis, terminal blocks, and more. Module: SCXI-1520; 8-chan. . Since you can also assign an SCXI-1314 as an accessory to the SCXI-1520, you should be aware that the signals in the 1314 and 1314T are different. The NI SCXI 1314 is a strain gauge input terminal block, mainly used with floating signals (the voltage signal is not referred to an absolute reference, such as earth or building ground); if this is how you have signals connected here versus the NI SCXI-1327, then it would explain the behavior difference. . I have connected one strain gauge as quarter gauge-I configuration in one channel. 4. Using the SCXI-1317 terminal block with the SCXI-1521/B module enables you to conveniently connect quarter-bridge strain gauges. SCXI-1320 Terminal Block SCXI-1314. It also has a 1120 card w/SCXI 1303 terminal block with type K thermocouple installed. I am connect a half bridge setting to SCXI-1314 terminal block. png ‏83 KB. Win7 Enterprise. About This Manual Conventions. 16 pages. Now, I need to calibrate the extensometer (OFFSET REMOVAL and CALIBRATION of SHUNT). Rated 0 /5 based on 0. For an upcoming test we plan to use an old SCXI-1001 chassis, an SCXI-1600 Daq, and 7 SCXI-1520's along with the SCXI-1314's to measure 50+ channels of strain gages. 2. You can also read this on page 4-27 and 4-28 of the SCXI-1520 User Manual and Specifications. Average Delivery 5-20 Days. Otherwise, you'll probably want to reference this KB on DAQmx calibrations . Note When connecting your signals to the SCXI-1313, follow the labeling on the SCXI-1313 for the appropriate module, as indicated in Figure 2. The SCXI-1314 terminal block is used with the SCXI-1520 universal. 저는 완전-브리지(full-bridge) 트랜스듀서(압력 트랜스듀서, 로드셀, 토크 트랜스듀서 등)를 가지고 있습니다. If you plan to use an SCXI-1104 or SCXI-1125 with a Remote SCXI configuration, you must update the firmware on your SCXI-2000 chassis or SCXI-2400 module. The problem I'm having is that t. The connector blocks have 3 feet of Belden 8723 signal cables installed on each channel. The task uses a SCXI-1000 chassis with a SCXI-1520 module and a SCXI-1314 terminal block. The SCXI-1520 is a universal strain gage input module that has a built in amplifier and automatic null compensation system. SCXI-1001: PXIe-1065: cDAQ 9178 cDAQ. Click the Chassis tab. 288. 注意 scxi モジュールには、ホットスワップ機能がありません。モ ジュール、ターミナルブロック、またはケーブルを着脱する前に、 必ずscxi シャーシの電源をオフにしてください。 1. scxi-1314 ターミナルブロックからカバーを取り外します。 2. MAX also has a setting for the default gains of the. . . This document provides the steps to install and configure a typical cascaded SCXI module system. Leave jumper W1 on the SCXI-1100 in the factory-default (parking) position. 124. SCXI-1126 Figure 2. This documents provides information on calibration service levels available for NI Products. 121. This installation guide describes how to install, configure, and use your BNC-2120 accessory with. SCXI 1314 is the connector block where you wire the strain gauges in quarter/half/full bridge configuration. 4. National Instruments 197882A-01 High-Voltage Attenuator Terminal Block. The BNC-2111 is an adapter you can connect to data acquisition (DAQ) devices. Mesurer les charges appliquées. C. Should I do anything differently? images. National Instruments SCXI-1520 8 Channel Universal SCXI Strain Gage Input Module. Connection verified; FullBridge I connection. Verify that open ports are electrically compatible with strain gauge 4. 1. This combination allows the user to easily link strain gauges via screw terminals. It is equipped with a 1520 card w/SCXI 1314 terminal block connected to an extensiometer and strain gage. The problem just started after inserting a similar module in the second slot. EN English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian český. 2. I used the SCXI-1520 Strain. Member AuthorThe SCXI-1326 terminal block is a shielded board with supports to connect it to the module front connector. The value of strain do display in LABVIEW EXPRESS. All Manuals. This is what I did. Close and lock the enclosure door. SCXI-1520 to SCXI-1314 Full-Bridge Connection. Right click on Devices and Interfaces and click Create New. . Apex Waves carries obsolete National Instruments Signal Conditioning eXtensions for Instrumentation (SCXI) modules, chassis, terminal blocks, and more. 114. In Stock. SCXI-1520 (Load cells) 2 SCXI-1314 (Load cells) 2 SCXI-1122(RTDs) 2 SCXI-1322 (RTDs) 2 SCXI-1161 (Relays) NI 6713 CWaveform generator)Rate the SCXI-1314. The policy on the equipment use outlines the recommended procedure for the sharing of CREPEC infrastructure recommended by the members of the CREPEC Executive. Run the signal wires through the strain-relief opening. SCXI-1314 PLCs/Machine Control from NATIONAL INSTRUMENTS 2-Year Warranty, Radwell Repairs - DISCONTINUED BY MANUFACTURER, TERMINAL BLOCK, LOW VOLTAGE. Each cantilever sensor is part of a shielded 1/4 Wheatstone bridge configuration. Mod5: SCXI-1520. The NI SCXI-1520 (Part Number: 777966-20, 186338-01) Universal Strain-Gauge Input Module can be utilized with the SCXI-1314 Screw Terminal Block, the SCXI-1310 Connector and Shell Assembly, the TBX-96 DIN. Attach the SCXI-1317 to the SCXI-1521/B using the thumbscrews. No other lines should be connected on the terminal block, because that could distrupt the input reading on the channel. SCXI-1327 Parts Locator Diagram 4. 10-03-2008 11:14 AM. The SCXI-1314 has eight possible channels for strain gage connections. I am using 10 channels to measure strain with quarter bridge-I completion. Free essays, homework help, flashcards, research papers, book reports, term papers, history, science, politicsIn the figure below, a connection diagram for wiring a strain gauge has been illustrated. 3. To install and use your SCXI-1314 terminal block, you need the following items: SCXI-1314 terminal block SCXI-1314 Universal Strain Terminal Block Installation Guide Eight precision 120 Ω resistors for use in quarter-bridge completion circuits (if using 120 Ω strain gauges) SCXI chassis SCXI-1520 module SCXI-1520 User Manual Re: SCXI-1314T. Verify that there is physically a means to connect strain gauge 5. Analog Output Channel Signal Connections on the SCXI-1124. Figure 3: Sample Connection Diagram for a Strain Gauge Input TaskChapter 2 Connecting Signals SCXI-1520 Set Bridge Configuration to Transducer SCXI-1314 Quarter Bridge – (gauge) – You must connect Shunt the shunt calibration Cal A wires externally using the terminal block screw connections. 326 National Instruments ¥ Tel: (800) 433-3488 ¥ Fax: (512) 683-9300 ¥ info@ni. . Otherwise, you'll probably want to reference this KB on DAQmx calibrations . Eight 120 ½resistors for use with 120 ½quarter-bridge strain gauges are included, but not installed. zero. Proven Zealot ‎11-08-2011 03:42 PM. I am trying to read a Sensotec load cell - model 41 (50,000 lb). Mod6: SCXI-1520. ThanksNI SCXI-1304 NI SCXI-1306 NI SCXI-1314 NI SCXI-1315 NI SCXI-1326 NI SCXI-1600. 7. SCXI TM SCXI-1520 User Manual SCXI-1520 User Manual May 2009 372583E-01. Providing accurate control systems in rehabilitation robotic has been a challenge for researchers. The task has been configured from a full bridge type-I strain gauge with internal excitation. 117. Expand the NI-DAQmx SCXI Chassis section and choose your chassis model and click Finish. With factory-installed and socketed 350 ½quarter-bridge completion resistors for each channel. 3 Results and Discussions. shunt-calibration and quarter-bridge resistors of your SCXI-1314 terminal block. . Analog Circuitry in the SCXI-1122. Find the National Instruments SCXI-1325 at our website: Click HERE. There are 88 screw terminals arranged in eight groups of 11. I connected the cable to the S - P + and PIN the SCI QTR 1314. 4 Class 2). com terminal block. When I condition and calibrate the load cell as a Full-Bridge Strain channel (shunt cal) my signal output is POSITIVE in compression. Type. Check for open ports on the device 3. 1) Open the DAQ card in MAX and Open the Test Panels. With this system, it is possible to measure only theherein are trademarks or trade names of their respective companies. com bold Bold text denotes items that you must select or click in the software, such as menu items and dialog box options. 00. The SCXI 1322 (Part Number: 777687-22) is designed to be used with the SCXI-1122 module. Once I right clicked SCXI 1001 under device and Interfaces in MAX>> test>>I found a pop up window as “Verify SCXI chassis: Configuration specifies a SCXI -1600 module but nothing was detected”. We offer repair services with a 1 week turnaround and calibration services with a 2 week turnaround. connect the SCXI-1001 containing the SCXI-1520 & SCXI-1314. TypeHi, I am trying to measure votalge ouput from a strain gauge attached to a cantilever beam. The SCXI-1520 module provides parallel measurement of up to 8-channels simultaneously, capturing and multiplexing into a single data stream to a PC acquisition card (National Instruments, M-Series PC-6221) with a maximum sampling rate of 250 kS/s. Figure 4-10. 96-Pin Female DIN to 88-Pin Female Screw Terminal, 10 V, PXI Module Mount Terminal Block —The TB-4330 provides an industrial PXI front-mounting Terminal Block for PXIe-4330 PXI Strain/Bridge Input Module. For a complete description of. 119. If you have an SCXI-2400 module, double-click the folder of the chassis that it is in, then right-click on the SCXI-2400 folder and select Properties. scxi-1314 ターミナルブロックからカバーを取り外します。 2. I have tried the following:-Disconnect power, power back on-system OK for a few seconds, then fails to recognize anything-Swap out USB cable connecting the 1600 to the PC-no change in problem-Check fuses (two by power cable. I had a working VI that could balance a wheatstone half bridge and read and record measurements. Figure 3: Sample Connection Diagram for a Strain Gauge Input Taskarinc & 1553 . View All (12) 0 Kudos Message 1 of 7From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Mph K 55 Manual, Netopia R910 Manual, Xbee Pro S1 Manual, 6es7 216-2ad00-0xb0 Manual, Body Language Manual, Scxi 1314 Manual, Tiger Rear End Manual ohcosmetics 4. Hi, How to configure in MAX the SCXI 1314(PXI 1052 and 1520) to take load cell measurement? I tried to create a task usin analog input ->strain, but it does not work. Being a universal strain gauge module there are several different inputs and excitation output configurations to ensure compatibility. 3a), with an active gage and a dummy gage, in order to eliminate, in the strain values, the effect of temperature variation. It is equipped with a 1520 card w/SCXI 1314 terminal block connected to an extensiometer and strain gage. 00. This is a list of products not supported by NI-DAQ 6. 9393. Terminal Blocks: SCXI 1314, 1315 . Description. SCXI-1191; SCXI-1192; SCXI -1313; SCXI-1314; TBX-1316 Back to Top. One load cell was connected to an HBM load indicator and the other to the SCXI 1520 and 1314 terminal block channel 0. Can anybody help?an SCXI-1314 terminal block, connect the DMM to the P0+ and P0– output terminals of the SCXI-1314. scxi 섀시 4‑Slot, AC Chassis for SCXI —The SCXI‑1000 is a rugged, low‑noise chassis that powers SCXI modules as well as handles all timing, trigger, and signal routing between other modules and SCXI modules. I tried programmatically stopping and starting the task, as well as reseting the device (SCXI 1520 + SCXI 1314), but this still does not apply the new scale to my continuously sampled data. 13 The load cell is connected to the DA strain module (SCXI 1520-1314 terminal) for full Wheatstone bridge. Sur ce chassis, je dispose du module SCXI-1520 avec le terminal block• A National Instruments model SCXI-1000 instrumentation chassis with model SCXI-1112 thermocouple input card and model SCXI-1520 strain amplifier (with SCXI-1314 interface card); and • A K-type thermocouple temperature sensor which is able to detect and initiate warnings or shut-down of the system in the event of excessive. Mechanical Dimensions. Call SCXI_Set_Excitation to set the excitation voltage to the desired value. The sampling rate was set at 1000 Hz, the cut-off frequency of the low-pass filter at 100 Hz, and the strains for a given applied load were. B-2 B. 1553. . $200. 117. Mod9: SCXI-1102 . Connector Accessory for E/M/S Series Devices. 777687-14 (SCXI-1314, Front Mounting Terminal Block) $ 239. I'm planning to use Signal Express to set the project up since the requirements for the data will be primarily logging. 1553.